Products
Accelerometer Calibration Systems
CS18 MF
Secondary calibration according to ISO 16063-21 (comparison method) of charge type, IEPE, voltage, capacitive and piezo-resistive sensors for acceleration, velocity and displacement, with Sine excitation with high accuracy
- Frequency range 3 Hz – 10 kHz
- Up to 500 m/s² acceleration amplitude
- Sine-, multisine-, random excitation
- Sine sweeps up to 20 kHz
- Calibration according to ISO 16063-21
- Eg. calibration of sensors for acceleration, charge type, IEPE, voltage…
CS18 HF
Secondary calibration according to ISO 16063-21 (comparison method) of charge type, ICP®, voltage, capacitive and piezo-resistive sensors for acceleration, velocity and distance, with Sine excitation with high accuracy. Available as Primary calibration system according to ISO 16063-11
- Frequency range 5 Hz – 20 kHz
- Up to 400 m/s² acceleration amplitude
- Sine-, multisine-, random excitation
- Sine sweeps up to 50 kHz
- Calibration according to ISO 16063-21
CS18 VLF
Secondary calibration according to ISO 16063-21 (comparison method) of charge type, ICP®, voltage, capacitive and piezo-resistive sensors for acceleration, velocity and distance, with Sine excitation with high accuracy. Available as Primary calibration system according to ISO 16063-11
- Frequency range 0.2 Hz – 160 Hz
- Up to 50 mm amplitude
- Up to 900 g payload
- Sine excitation
- Calibration according to ISO 16063-21
CS18P Seismic
System for high quality primary calibration of seismometers, geophones and heavy vibration transducers with sinusoidial excitation
- Frequency Range: 0.1 Hz – 400 Hz
- Sensor Mass: up to 50 kg (vertical)
- Calibration of sensors according to ISO 16063-11 (Primary Calibration, Method 3)
CV-10 Mobile Calibration System
Portable Calibration Solution for Vibration Sensors
The CV-10 Mobile Calibration System is a compact, battery-powered calibrator designed for on-site testing and calibration of accelerometers, velocity sensors, proximity probes, and other motion transducers. With traceable calibration, integrated signal conditioning, and up to 10 hours of battery operation, it enables fast and reliable sensor verification wherever it is needed.
Key Specifications
- Frequency Range: 5 Hz – 10 kHz
- Maximum Displacement: 5 mm pk-pk
- Maximum Acceleration: 200 m/s²
- Maximum DUT Mass: 900 g
- Battery Operation: Up to 10 hours
- Weight: 9 kg
- Signal Inputs: IEPE, Charge, Voltage, 4–20 mA
Applications
- Accelerometer calibration
- Velocity sensor calibration
- Proximity probe testing
- Vibration meter verification
- Industrial condition monitoring
- Ground vibration testing (GVT)
- Research & development
- Aerospace and aviation testing
- Automotive testing
- Field and laboratory calibration